Report 18126203 EOS EX082 Temporary Print e-AD
Report 18126203 EOS EX082 Temporary Print e-AD
Methods
CreatePrinteADBuffer
procedure CreatePrinteADBuffer(eAD_EntryNo: Integer)
Parameters / Return Value
- eAD_EntryNo
Integer
GetInfo_01
procedure GetInfo_01()
GetInfo_02
procedure GetInfo_02()
Events
OnBeforeCreatePrinteADBuffer
local procedure OnBeforeCreatePrinteADBuffer(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var IsHandled: Boolean)
This event is raised before creating the buffer.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_1
local procedure OnBeforeGetInfo_1(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_1() - “Document header info”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number.
ParentDescNo
Text[200]
Description of the parent
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_2
local procedure OnBeforeGetInfo_2(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_2() - “Consignor”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number.
ParentDescNo
Text[200]
Description of the parent
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_3
local procedure OnBeforeGetInfo_3(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_3() - “Shipping Place”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number.
ParentDescNo
Text[200]
Description of the parent
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_4
local procedure OnBeforeGetInfo_4(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_4() - “Shipping Office”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number.
ParentDescNo
Text[200]
Description of the parent
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_5
local procedure OnBeforeGetInfo_5(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_5() - “Recipient”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number.
ParentDescNo
Text[200]
Description of the parent
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_6
local procedure OnBeforeGetInfo_6(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_6() - “Recipient additional info”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number.
ParentDescNo
Text[200]
Description of the parent
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_7
local procedure OnBeforeGetInfo_7(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_7() - “Place Destination”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number.
ParentDescNo
Text[200]
Description of the parent
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_8
local procedure OnBeforeGetInfo_8(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_8() - “Destination Office”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number.
ParentDescNo
Text[200]
Description of the parent
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_9
local procedure OnBeforeGetInfo_9(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_9() - “DAA Info”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number.
ParentDescNo
Text[200]
Description of the parent
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_12
local procedure OnBeforeGetInfo_12(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var eADDetail: Record "EOS EX082 e-AD Detail"; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_12() - “Guarantor Details”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number. ParetNo. has a progressive number, which is the index of the detail.
ParentDescNo
Text[200]
Description of the parent
eADDetail
Record "EOS EX082 e-AD Detail"
filtered Guarantor details of the document. For each detail insert the lines on buffer
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_13
local procedure OnBeforeGetInfo_13(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_13() - “Transport”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number.
ParentDescNo
Text[200]
Description of the parent
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_14
local procedure OnBeforeGetInfo_14(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_14() - “Transport Company”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number.
ParentDescNo
Text[200]
Description of the parent
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_15
local procedure OnBeforeGetInfo_15(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_15() - “First Transport”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number.
ParentDescNo
Text[200]
Description of the parent
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_16
local procedure OnBeforeGetInfo_16(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var eADDetail: Record "EOS EX082 e-AD Detail"; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_16() - “Transport Details”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number. ParetNo. has a progressive number, which is the index of the detail.
ParentDescNo
Text[200]
Description of the parent
eADDetail
Record "EOS EX082 e-AD Detail"
filtered Transport Details of the document. For each detail insert the lines on buffer
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_17
local procedure OnBeforeGetInfo_17(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var eADDetail: Record "EOS EX082 e-AD Detail"; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_17() - “Goods Details”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number. ParetNo. has a progressive number, which is the index of the detail.
ParentDescNo
Text[200]
Description of the parent
eADDetail
Record "EOS EX082 e-AD Detail"
filtered Product Details of the document. For each detail insert the lines on buffer
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_17_1
local procedure OnBeforeGetInfo_17_1(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var eADDetail: Record "EOS EX082 e-AD Detail"; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_17_1() - “Packaging Details”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number. ParetNo. has a progressive number, which is the index of the detail.
ParentDescNo
Text[200]
Description of the parent
eADDetail
Record "EOS EX082 e-AD Detail"
filtered Packaging Details of the document. For each detail insert the lines on buffer
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_17_2
local procedure OnBeforeGetInfo_17_2(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var eADDetail: Record "EOS EX082 e-AD Detail"; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_17_2() - “Wine Details”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number. ParetNo. has a progressive number, which is the index of the detail.
ParentDescNo
Text[200]
Description of the parent
eADDetail
Record "EOS EX082 e-AD Detail"
filtered Product Details of the document. For each detail insert the lines on buffer
IsHandled
Boolean
if true, no following app code will be executed
OnBeforeGetInfo_17_2_1
local procedure OnBeforeGetInfo_17_2_1(var TempPrinteADBuffer: Record "EOS EX082 Print e-AD Buffer"; var eADHeader: Record "EOS EX082 e-AD Header"; var ParentNo: Code[20];var ParentDescNo: Text[200]; var eADDetail: Record "EOS EX082 e-AD Detail"; var IsHandled: Boolean)
This event is raised at the beginning of the procedure GetInfo_17_2_1() - “Wine Treatment Details”. Use it to insert lines in the TempPrinteADBuffer. Field “No.” is the line No. Field “Description No.” is the line descr. Field “Description” contains the line information.
Parameters / Return Value
TempPrinteADBuffer
Record "EOS EX082 Print e-AD Buffer"
Buffer to modify
eADHeader
Record "EOS EX082 e-AD Header"
Record “EOS EX082 e-AD Header”
ParentNo
Code[20]
No. of the parent line. Rows are grouped with this number. ParetNo. has a progressive number, which is the index of the detail.
ParentDescNo
Text[200]
Description of the parent
eADDetail
Record "EOS EX082 e-AD Detail"
filtered Product Details of the document. For each detail insert the lines on buffer
IsHandled
Boolean
if true, no following app code will be executed
Feedback
Was this page helpful?
Glad to hear it! Please tell us how we can improve.
Sorry to hear that. Please tell us how we can improve.